GSO IEC 61238-1-3:2021
IEC 61238-1-3:2018
								
									
									Gulf Standard
								
								
								
									 
									Current Edition
									
								
								
									·
									Approved on
									01 July 2021
								
							
							Compression and mechanical connectors for power cables - Part 1-3: Test methods and requirements for compression and mechanical connectors for power cables for rated voltages above 1 kV (U<sub>m</sub> = 1,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) tested on non-insulated conductors
GSO IEC 61238-1-3:2021 Files
				                	 
				                    No files for this standard are available in the store currently.
				                
  
			                
			                
								
																								
												
													Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
																								
											
										GSO IEC 61238-1-3:2021 Scope
									IEC 61238-1-3:2018 applies to compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV), for example buried cables or cables installed in buildings, having
a) conductors complying with IEC 60228 having nominal cross-sectional areas between 2,5 mm2 and 1 200 mm2 for copper and between 16 mm2 and 1 200 mm2 for aluminium, excluding Milliken conductors;
b) a maximum continuous conductor temperature not exceeding 90 °C.
This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact.
The object of this document is to define the type test methods and requirements which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused conductors.
This first edition, together with IEC 61238-1-1 and IEC 61238-1-2, cancels and replaces IEC 61238-1:2003.
This edition includes the following significant technical changes with respect to IEC 61238-1:2003:
a) The scope has been widened to cover connectors for conductors from 10 mm2 down to 2,5 mm2 and has been limited to 1 200 mm2 for connectors for copper and aluminium conductors because test experience and applications are rare for conductors of larger cross-sectional areas.
b) A new mechanical class has been introduced to satisfy the demand for connectors subjected to higher mechanical forces than those specified in Class 1 for conductors of larger cross-sectional areas.
c) For the electrical test, a maximum elevated heating current has been set in order to avoid unrealistic current densities during the test which may change the properties of tested connectors.
d) For the short-circuit test, the method of calculation and requirements have been updated.
e) For the mechanical test, the methods and requirements have been updated.
f) A proposal for an electrical test on cable terminal lugs for application in separable connectors has been introduced.
							
						
					a) conductors complying with IEC 60228 having nominal cross-sectional areas between 2,5 mm2 and 1 200 mm2 for copper and between 16 mm2 and 1 200 mm2 for aluminium, excluding Milliken conductors;
b) a maximum continuous conductor temperature not exceeding 90 °C.
This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact.
The object of this document is to define the type test methods and requirements which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused conductors.
This first edition, together with IEC 61238-1-1 and IEC 61238-1-2, cancels and replaces IEC 61238-1:2003.
This edition includes the following significant technical changes with respect to IEC 61238-1:2003:
a) The scope has been widened to cover connectors for conductors from 10 mm2 down to 2,5 mm2 and has been limited to 1 200 mm2 for connectors for copper and aluminium conductors because test experience and applications are rare for conductors of larger cross-sectional areas.
b) A new mechanical class has been introduced to satisfy the demand for connectors subjected to higher mechanical forces than those specified in Class 1 for conductors of larger cross-sectional areas.
c) For the electrical test, a maximum elevated heating current has been set in order to avoid unrealistic current densities during the test which may change the properties of tested connectors.
d) For the short-circuit test, the method of calculation and requirements have been updated.
e) For the mechanical test, the methods and requirements have been updated.
f) A proposal for an electrical test on cable terminal lugs for application in separable connectors has been introduced.
Best Sellers From Electrical Sector
GSO 2530:2016
   
                        
                            
                            
                                Gulf Standard
                            
                        
                        
                            
                            
                                
                                Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
                            
                        
                        
                        OS GSO 2530:2016
   
                        
                            
                            
                                Omani Standard
                            
                        
                        
                            
                            
                                
                                Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
                            
                        
                        
                        OS GSO 34:2007
   
                        
                            
                            
                                Omani Standard
                            
                        
                        
                            
                            
                                
                                LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
                            
                        
                        
                        GSO 34:2007
   
                        
                            
                            
                                Gulf Technical Regulation
                            
                        
                        
                            
                            
                                
                                LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
                            
                        
                        
                        Recently Published from Electrical Sector
GSO IEC/IEEE 60214-2:2022
   
                        
                            IEC/IEEE 60214-2:2019 
                        
                        
                    
                            
                            
                                Gulf Standard
                            
                        
                        
                            
                            
                                
                                Tap-changers - Part 2: Application guidelines
                            
                        
                        
                        GSO IEC 60076-22-2:2022
   
                        
                            IEC 60076-22-2:2019 
                        
                        
                    
                            
                            
                                Gulf Standard
                            
                        
                        
                            
                            
                                
                                Power transformers - Part 22-2: Power transformer and reactor fittings - Removable radiators
                            
                        
                        
                        GSO IEC 60076-7:2022
   
                        
                            IEC 60076-7:2018 
                        
                        
                    
                            
                            
                                Gulf Standard
                            
                        
                        
                            
                            
                                
                                Power transformers - Part 7: Loading guide for mineral-oil-immersed power transformers
                            
                        
                        
                        GSO IEC 62841-2-4:2022
   
                        
                            IEC 62841-2-4:2014 
                        
                        
                    
                            
                            
                                Gulf Standard
                            
                        
                        
                            
                            
                                
                                Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery - Safety - Part 2-4: Particular requirements for hand-held sanders and polishers other than disc type